Foul Air Trap
Fits:
KlassikDrain - K900 & KS900 catch basins
PowerDrain - SK900 catch basin
ChemDrain - CK900 & CSK900 catch basins |
A polypropylene foul air trap that fits into
front or side of in-line catch basins. Rubber ‘O’ rings seal the trap into the catch basin
(liquid soap is recommended to help ease
trap into position). A coupler is required to
connect Schedule 40 4” plain end pipe to
underground pipe system. |
|

Inside catch basin - removable black rubber trap plug at top, 4" pipe outlet at bottom. |
|
|
Oval to Round Pipe Connection
Fits:
KlassikDrain - K100S & KS100S
PowerDrain - S100K
ChemDrain - C100, CK100S & CS100K |
Oval to round polypropylene adapter for
bottom drill-out on 4” polymer concrete
channels. Schedule 40 6” plain end can be
solvent welded to underground pipe system.
Seal to channel using appropriate flexible
sealant.
|
|
|
Vertical Outlet Strainer
Fits:
KlassikDrain - K100S & KS100S
PowerDrain - S100K
ChemDrain - C100, CK100S, CS100K,
CH80, CH100, CH80K, CH100K & CH100SK
SlabDrain - H80, H100, H80K, H100K &
H100SK
FlowDrain - FG100 & FG200 |
Strainer for 4” vertical outlets, prevents large particles of debris flowing into
underground pipe system and causing
blockages. |
|
|
Installation Devices
Fits:
KlassikDrain - K100S & KS100S
PowerDrain - S100K
ChemDrain - C100, CK100S & CS100K |
The channel clamp sits at every channel
joint along the run. The clamp fits around
the profiled end detail and holds the joint
tight. Rebar inserted at the sides is used to
position channels. The clamp keeps the system level during
concrete pour. One clamp is required for
every channel joint. |


Clamp assembled across
two channels>
|
 |
|
|
Channel Hanger
Fits:
KlassikDrain - K100S & KS100S
ChemDrain - C100, CK100S, CH80, CH100,
CH80K & CH100K
SlabDrain - H80, H100, H80K, H100K |
The two-part channel hanger fits inside the
locking bar recess and provides a quick and
easy way to hang the system from 2 x 4’s.
The hanger also braces the channel to
prevent closing during concrete pour. |
|
|
PowerLok Hanger
Fits:
PowerDrain - S100K
ChemDrain - CS100K, CH100SK
SlabDrain - H100SK |
The two-part PowerLok hanger fits under the
anti-shunt lugs on the rail. The hanger fits
across the joint of two channels and assists
in alignment. The hanger also braces the
channel to prevent closing during concrete
pour. |
 |
One PowerLok hanger is required for every channel joint. PowerLok hangers can be reused.
5/16 - 18 x 3.0 bolt supplied
To hang S300K, use M10 bolts and 2 x 4’s
across channel and bolt to M10 thread in widgets
in the ductile iron rail (8 per meter). |
|