Lightweight, 4" wide, polyethylene channel with matching grate.
- Attractive lightweight UV resistant polyethylene channel and grate
- Interlocking end profiles make installation quick and easy
- Grate snap fits into the channel
- Dual purpose end cap/outlet caps available
- Smooth channel surface is easy to clean
- 4" vertical outlet molded to base of channel
|

|
Homedrain Product Data
| Description |
|
Part |
|
Length |
Width |
Height |
Weight |
|
|
No |
|
inches |
mm |
|
inches |
mm |
|
inches |
mm |
|
lbs |

|
Channel with grate black |
|
90860 |
|
39.4" |
1000 |
|
5.3" |
135 |
|
4.0" |
100 |
|
6.7 |
|
|
|
|
|
|
|
|
|
| Channel only black |
|
39.4" |
1000 |
5.3" |
135 |
4.0" |
100 |
4.3 |
| Channel only gray |
|
39.4" |
1000 |
5.3" |
135 |
4.0" |
100 |
4.3 |
|
|
|
|
|
|
|
|
|
| Grate only black |
|
39.4" |
1000 |
5.3" |
135 |
- |
- |
2.4 |
| Grate only gray |
|
39.4" |
1000 |
5.3" |
135 |
- |
- |
2.4 |
| Grate only green |
|
39.4" |
1000 |
5.3" |
135 |
- |
- |
2.4 |
| Grate only brick |
|
39.4" |
1000 |
5.3" |
135 |
- |
- |
2.4 |
|
|
|
|
|
|
|
|
|
| Closing / outlet end cap - black |
79813 |
- |
- |
5.3" |
135 |
4.0" |
100 |
0.5 |
| Closing / outlet end cap - gray |
|
- |
- |
5.3" |
135 |
4.0" |
100 |
0.5 |
| 4" bottom outlet pipe |
HD004 |
- |
- |
- |
- |
- |
- |
2.9 |
|

Installation
1. Prepare a trench and fix a line at the required finished height. If channel will be exposed to vehicles, embed base and sides in 4” of good quality concrete.
2. Position outlet channel in the trench and ensure that it is level. Connect outlet pipe to the drain.
3. Lay the remaining channels, working away from outlet, and fit end caps.
4. Place grates upside down in channel and backfill with surrounding surface material.
5. Ensure that the finished surface is approximately 1/8” higher than the channel to assist water drainage. Reposition grates correct way up. |
|
|
|